Home > Technical Articles
2026-11-16
A spring probe is a mechanical spring, a sliding contact and a signal path in one component. When a fixture starts producing intermittent failures, the probe is usually blamed last and replaced first. A short measurement routine, done properly, tells you whether the probe is actually at fault.
Every probe has a rated travel, and the contact force is specified at a point on that travel, usually two thirds of it. A fixture that compresses the probe to 40 % of travel runs at a fraction of the rated force. The result is a contact that looks fine on a static bench test and opens when the fixture frame flexes under load.
| Bare copper or gold pad | Light force is enough; the risk is pad damage rather than oxide penetration. |
| HASL or contaminated pad | Higher force and a crowned or serrated tip help break through the layer. |
| Fine pitch array | Force per probe drops because the total force on the board is limited; check total load, not just single-probe force. |
| High-current path | Use a probe rated for the current and derate for multiple probes carrying current at the same time. |
Putting a handheld ohmmeter across a probe and a return path measures the probe plus the leads plus the return. On a 50 mOhm probe, 200 mOhm of lead and clip resistance dominates. The usable method is four-wire: force current through the probe and the return, and measure voltage at the probe tip and at the return point with separate sense leads.
Two practical details decide whether the number means anything:
A new probe may read 20 to 50 mOhm. What matters is the trend across a production run. A rise of a few milliohms over tens of thousands of cycles is normal bedding-in; a step change after cleaning is a sign that the plating has worn through. Keep a log per fixture position, not per probe batch, because the position tells you about alignment and the batch tells you about supplier consistency.
Cleaning with isopropyl alcohol and a lint-free swab recovers contamination, not wear. Replacing a single probe in an array without checking the neighbours usually moves the failure to the next weakest position.
Measure travel at four corners of the fixture, record four-wire resistance on ten representative probes, check total board load against the fixture specification, and inspect tips under magnification. That routine finds most intermittent-contact causes before a production lot does. The test probe and pin range lists force and travel options by series, and the plug and socket gauge range covers the mating-side checks.
Contact: Eason Wang
Phone: +86-13751010017
Tel: +86-755-33168386
Email: info@iec-equipment.com