The Indicator Circuit Behind a Test Probe: 40 V, a Resistor and the Contact Area

2026-11-18

An accessibility test ends in a yes or no: did the probe touch a live part. The probe supplies geometry; the indicator supplies the answer. Most of the argument at the end of a test is about the indicator.

The circuit is usually a low-voltage lamp in series with the probe tip and the supply, with a resistor to limit current. The voltage is typically 40 V to 50 V, the current a few milliamps, and the lamp is chosen so that a film of contamination does not light it.

Why 40 V and not 230 V

The indicator must not damage the sample. At 40 V a thin insulating film survives the test, which is the point: a real user touching the same surface would not break down a 0.05 mm film either. Testing at mains voltage would break the film and report a hazard that does not exist in service.

ElementTypical valueEffect on the verdict
Indicator voltage40 V to 50 V AC or DCHigh enough to light a lamp, low enough not to puncture films
Series resistorSets current to a few mAProtects the sample and the lamp
LampFilament or LED with thresholdFilament shows short contact; LED may miss it
Probe tip materialBrass or steel, cleanOxide on the tip reads as an insulator
Contact areaTip radius, not the whole fingerA 2 mm radius is the whole contact patch
Circuit returnTo the earthed enclosureA floating return gives no reading

A filament lamp is slower than an LED and that is an advantage: it averages out intermittent contact and shows a steady glow only where the contact is real.

Four ways to get the wrong answer

  • Dirty tip. A finger that has been handled all day has a film on the tip. Wipe it and re-test before recording a pass.
  • Floating reference. If the return is not connected to the part under test, the lamp stays dark and the sample passes for the wrong reason.
  • Too much force. Pushing the probe deforms a plastic boss and the tip reaches metal it could not reach in service. Use the force the clause specifies, no more.
  • Judging the glow. A dim glow at the edge of visibility is the hardest call in the test. Photograph it and let a second person decide.

Making the record useful

For every access point, record the probe used, the force, the result, and the depth of insertion if the probe could move. A report that says "no contact" for twelve openings tells the designer nothing about which opening was 1 mm from contact.

The indicator circuit is part of the instrument, not an accessory: it should be checked against a known live part at the start of every session, which takes ten seconds and catches the dirty tip, the broken lead and the flat battery in one go. Our probe sets include the lead and lamp holder, and the geometry of each probe is listed in the technical notes.

Standards referenced: IEC 61032, IEC 60529 clause 13.1, IEC 60950-1 clause 2.1.1 (indicator circuit practice), UL 507.

What a false pass costs downstream

An accessibility test that passes a 4 mm gap reports a design as safe when a 12 mm finger reaches a live terminal at 230 V. The cost of that error is not in the laboratory; it is in the field, in a recall that starts with a single incident and ends with a 5,000 unit return.

  • Verify the indicator against a known live part at the start of every session.
  • Photograph the glow, not just the conclusion.
  • Record which probe, which force and which opening, every time.