Working Travel, Overtravel and the Contact That Does Not Come Back

2026-11-17

A spring probe is specified by a travel figure that almost nobody uses in service. Working travel is where the spring is designed to operate; overtravel is where the fixture pushes it to take up tolerance. Those are two different places, and the contact resistance is not the same at both.

The failure that follows is subtle: a fixture that works perfectly for six months starts giving intermittent readings on one station, and the probe is blamed without anyone measuring how far it is being compressed.

The three travel numbers

TermMeaningTypical relationship
Full strokePlunger travel from free to fully bottomedThe largest number on the sheet
Working travelThe range where spring force and resistance are specifiedOften two thirds of full stroke
OvertravelTravel beyond working point available for tolerance take-upThe last third
Spring force at working pointThe force the datasheet quotesMeasured, not calculated
Force at overtravelHigher, and rising steeply near the bottomCan double over the working value
Contact resistanceSpecified at working point, not at bottomRises if the barrel is over-compressed

Pushing a probe to full stroke is not automatically bad, but it changes the mechanics. The spring reaches its solid height, the plunger stops moving and the fixture’s remaining travel goes into the barrel and the receptacle. That load path is the one that cracks solder joints and enlarges the receptacle bore.

What over-compression does to the reading

Contact resistance depends on the force at the contact point and on the condition of the barrel. Over-compression raises force, which lowers resistance in the short term and wears the barrel faster. Once the plating on the plunger or the barrel is worn through, the base metal oxidises and resistance climbs by an order of magnitude between cleanings.

The tell is a resistance that is fine immediately after cleaning and rises over a shift. That is wear, not contamination, and no amount of cleaning solvent fixes it.

Specifying for a fixture that lasts

  • Design the fixture to compress to the working point plus half the overtravel, not to full stroke. That leaves margin for part tolerance without bottoming the spring.
  • State the force at the working point in the fixture drawing. A probe chosen for its travel alone may deliver half the force the contact needs.
  • Use a probe with a flat or crowned tip for pads, and a sharp tip only where the oxide must be penetrated. A sharp tip that penetrates also wears.
  • Keep a spare station. Probes are consumables; a fixture with no spare position stops production for a 20 cent part.

Checking a probe in place

Measure the compressed length with a depth gauge while the fixture is closed, and compare it with the working travel in the datasheet. Measure resistance at that compression with a four-wire method, not with a two-wire meter, because the lead resistance is the same order as the value you are checking. Then measure again after 10,000 cycles: a probe whose resistance has doubled is at the end of its life even if it still springs back.

Choosing the right body diameter and tip style matters more than the brand. A spring probe selected against the working point, the force and the tip geometry will outlast a cheaper one chosen by length, and the site index groups the probes by barrel diameter so the receptacle can be matched at the same time.

The numbers a fixture drawing should carry

A fixture drawing that specifies only the probe part number is incomplete. Four numbers belong on it: the compressed length at the working point, the force at that length, the overtravel left for part tolerance, and the resistance limit for a good contact. In a typical 2.5 mm pitch fixture the working point is 4.3 mm of a 6.4 mm stroke, the force there is 1.2 N, and the remaining 2.1 mm covers a part thickness tolerance of 0.2 mm plus the fixture wear allowance.

Set the resistance limit from the application, not from the probe datasheet: a probe specified at 50 mΩ will read 80 mΩ after 100,000 cycles and still be within its own life. If the test needs 100 mΩ, the maintenance interval is decided by the resistance trend, not by the calendar.

Standards referenced: IEC 61032; IEC 60529.