Home > Technical Articles

Test Finger Joints: 90 Degrees, 0.5 N·m and the Wrist That Must Not Give

2026-11-17

The jointed test finger is the most recognisable object in electrical safety testing and the least understood as a mechanism. Everyone knows the 12 mm sphere and the 80 mm baffle. Far fewer know that the two knuckles have a specified torque, and that a finger whose joints are too stiff tests a different product from the one on the drawing.

The finger is a simulation of a hand. It bends because a hand bends, and the resistance at the joint is what stops the simulation from being either a rigid rod or a limp chain.

The dimensions that define it

FeatureValueFunction
Tip sphere12 mm radius, 80 mm long finger bodyThe reach and the contact geometry
Baffle50 mm diameter, 100 mm from the tipStops the finger entering deeper than a hand
Joint 1 and joint 2Two hinges, 90 degrees of free travelAllow the finger to follow a bent path
Joint torqueAround 0.5 N·m to move a jointDistinguishes a finger from a rod
Applied forceSet by the clause, commonly 20 N or 30 NDecides whether an opening is forced
Test durationUp to one minute in each positionLets the material relax

The 80 mm baffle is the number that decides most arguments. It represents the palm, so anything the finger can reach beyond 80 mm is reachable by a hand, and anything it cannot is not. A finger with a missing or shortened baffle will reach further and produce failures that do not exist.

Why joint torque matters

A finger with tight joints behaves like a curved rod. It enters an opening at a fixed angle and either touches a live part or does not. A finger with correct joints follows the path a real finger would take, bending around a barrier and continuing into a space the rigid version could never enter. The second finger finds hazards the first one misses.

The opposite error is a finger with loose joints: it droops, enters at an angle the real hand could not achieve, and produces failures that a person could not reproduce. Both errors are invisible unless the joint is checked.

Checking the joint in a workshop

  • Hang a known mass from the tip with the finger horizontal and the joint free. The angle it reaches is a proxy for torque and is repeatable enough to detect a change.
  • Check for play, not just stiffness. A worn hinge with 0.3 mm of side play changes the effective length of the finger and the angle of the tip.
  • Look at the hinge pin. A pin that has been peened to tighten a joint will loosen again within a week of use.

Using it without fooling yourself

Apply the force in the direction a person would push, not in the direction that finds the hole. Hold for the full period: a moulded opening that yields after 30 seconds has failed, and a ten second push will not show it. Rotate the finger through the joint range while it is in the opening, because a hazard behind a lip is exactly what the joints exist to find.

Record the position, the force, the depth reached and whether a joint was at its stop. A jointed test finger with a marked depth scale and a calibrated joint is the only version worth using for a formal test, and the site index lists the accessories that go with it.

Standards referenced: IEC 61032; IEC 60529.