The jointed test finger is the most recognisable object in electrical safety testing and the least understood as a mechanism. Everyone knows the 12 mm sphere and the 80 mm baffle. Far fewer know that the two knuckles have a specified torque, and that a finger whose joints are too stiff tests a different product from the one on the drawing.
The finger is a simulation of a hand. It bends because a hand bends, and the resistance at the joint is what stops the simulation from being either a rigid rod or a limp chain.
| Feature | Value | Function |
| Tip sphere | 12 mm radius, 80 mm long finger body | The reach and the contact geometry |
| Baffle | 50 mm diameter, 100 mm from the tip | Stops the finger entering deeper than a hand |
| Joint 1 and joint 2 | Two hinges, 90 degrees of free travel | Allow the finger to follow a bent path |
| Joint torque | Around 0.5 N·m to move a joint | Distinguishes a finger from a rod |
| Applied force | Set by the clause, commonly 20 N or 30 N | Decides whether an opening is forced |
| Test duration | Up to one minute in each position | Lets the material relax |
The 80 mm baffle is the number that decides most arguments. It represents the palm, so anything the finger can reach beyond 80 mm is reachable by a hand, and anything it cannot is not. A finger with a missing or shortened baffle will reach further and produce failures that do not exist.
A finger with tight joints behaves like a curved rod. It enters an opening at a fixed angle and either touches a live part or does not. A finger with correct joints follows the path a real finger would take, bending around a barrier and continuing into a space the rigid version could never enter. The second finger finds hazards the first one misses.
The opposite error is a finger with loose joints: it droops, enters at an angle the real hand could not achieve, and produces failures that a person could not reproduce. Both errors are invisible unless the joint is checked.
Apply the force in the direction a person would push, not in the direction that finds the hole. Hold for the full period: a moulded opening that yields after 30 seconds has failed, and a ten second push will not show it. Rotate the finger through the joint range while it is in the opening, because a hazard behind a lip is exactly what the joints exist to find.
Record the position, the force, the depth reached and whether a joint was at its stop. A jointed test finger with a marked depth scale and a calibrated joint is the only version worth using for a formal test, and the site index lists the accessories that go with it.
Standards referenced: IEC 61032; IEC 60529.