Probe Tip Radius: What a Tenth of a Millimetre Changes in an Accessibility Test

2026-11-22

Every test probe ends in a defined shape: a sphere, a cone, a pin with a rounded end. That shape is not decoration. It decides how the probe behaves when it meets a narrow slot, a chamfered edge or a soft gasket — and it is the part of the tool that wears first.

Why the radius matters more than the diameter

Two probes can share the same diameter and behave differently because their tips differ. A 12 mm sphere meets a 13 mm slot by touching both walls at once; the same 12 mm cylinder with a flat end meets the same slot by catching on the first edge. The standard specifies a sphere because the sphere is what a fingertip approximates.

When the sphere wears, three things change together:

The contact point moves. A flattened tip contacts a curved surface over an area instead of at a point, so the probe starts to "sit" on a chamfer instead of sliding past it.

The effective length changes. A 0.1 mm flat on a 12 mm tip is 0.1 mm less penetration before the probe stops. On a shallow recess that is the difference between reaching the live part and not.

The insertion force spreads. The same 30 N applied through a flat instead of a point produces a different pressure distribution, and a soft gasket deforms differently.

Tip conditionWhat it does in a narrow slotEffect on verdict
correct sphereenters to the stop faceas designed
flattened 0.1 mmcatches on the entry chamferreports "not accessible" too early
burr or nickscratches the part, dragsunrepeatable, operator-dependent
rounded by polishingslips past a marginal openingreports "accessible" too late

How the tip actually wears

The wear is not random. A probe is pressed against painted metal, moulded plastic and the occasional burr. The tip contacts the hardest thing it meets, and over a few thousand insertions the sphere develops a small flat exactly where the load concentrates — usually slightly off-axis, because operators do not push perfectly straight.

A probe used only on soft plastics can look perfect after years. A probe used on painted steel enclosures shows a visible flat within months. The tool's history matters more than its age.

Checking the tip in thirty seconds

A loupe at 10× with raking light answers the question. The test is whether the tip still behaves as a sphere:

Look for a bright spot. A sphere under raking light shows a curved gradient. A flat shows a uniform bright patch with a hard edge. That edge is the wear boundary.

Roll it on paper. A spherical tip leaves a single point mark; a flattened one leaves a small smudge or a short line.

Compare with a spare. Keeping one unused probe of each type is the cheapest reference standard in the lab. Side by side at 10×, a worn tip is obvious; described in words, it is arguable.

What to do when the tip is worn

Tips are not field-repairable. Polishing a flat back into a sphere by hand changes the radius in a way nobody can verify, and a re-polished tip is a non-standard tool. Replacement is the only defensible answer.

The practical rule: a probe is a consumable with a service life measured in insertions, not years. If a lab runs 200 accessibility tests a month on painted enclosures, it should budget for replacing its most-used probe annually, and should check the tip monthly rather than at calibration.