The joint on a test probe is a pivot with a defined freedom of movement. Over time it develops play — free movement before any resistance is felt. Play changes where the probe tip ends up, and the change is always in the direction of reaching further.
A new joint moves smoothly with slight damping. A worn joint has a small range at each pivot where the segments move without any load on the tip. That range is play, and it accumulates at both joints.
The effect on a reach test is direct: the operator pushes, the joint takes up the play before transmitting force, and the tip travels further along its path than a real finger would.
| Joint state | Behaviour under load | Effect on result |
|---|---|---|
| new, damped | transmits force, follows contour | as specified |
| slight play | small free travel first | reaches a little further |
| loose | folds before pressing | false "accessible" findings |
A finger does not have play. Its joints resist until the force exceeds what the ligaments allow. A probe with play has no equivalent resistance in its free range, so any force at all produces movement.
The result: a probe with play finds access that a finger would not. Products get rejected for a hazard that does not exist, and the design gets changed for the wrong reason.
Hold the probe body, let the finger hang, and measure the tip's free movement at the joint. A millimetre or two at the tip corresponds to a small angle at the pivot, and it is enough to matter.
A more repeatable method: clamp the body, apply a small known force at the tip in each direction, and measure the displacement before the joint resists. That displacement is the play.
The standard specifies the joint's range of movement (90 degrees, 0 to +10) but not its resistance. That silence is why play goes unchecked — there is no number in the document to compare against.
The practical response is an internal limit. "No perceptible free movement at the tip under 1 N" is a workable rule, written into the inspection instruction rather than the standard.
A joint with play can sometimes be tightened, but the tightening usually changes the damping and can make the joint stiff. A stiff joint fails in the other direction — it will not follow a contour and under-reports reach.
For probes used in type testing, replacement is the safer choice. For probes used in routine production checks, a documented tightening with a re-check of the damping is acceptable.
Four items at the joint: range of movement, damping (does it hold position when released), play (free travel before resistance), and plane alignment (both joints coplanar, bending the same way).
The fourth is the one most often wrong after a repair, because reassembly can rotate one joint 90 degrees without anything looking amiss.